Model No.: XF3700-P3
Production Capacity: 3000
Delivery Date: Within 2 Days
Doppler scan: 3D Ultrasonic scanner
Clinical ultrasound: Ultrasound machine
Doppler ultrasonic scanner: Power Doppler
Heart doppler scan: Portable ultrasonic machine
Means of Transport: Ocean,Land,Air
Packing: Package Size:540×300×560(le...
Brand Name: XianFeng
USG: Laptop ultrasound
Notebook ultrasound: Portable Ultrasound
B mode ultrasound: Abdominal ultrasound

This color doppler ultrasound systemic applications include abdominal, obstetric, gynecological, cardiac, vascular, urinary, small organ, breast, etc.

This is a laptop full digital color ultrasound diagnosis system,integrand embedded XP platform performance of stable and affordable.It is a research and development of XF technical team combined with market demand in the XF7800 type main based on the development and design new style,thin and light, good carrying, appearance is compact, the function is powerful, with types of probe can support more, image processing and measuring package software is rich, full blood flow image clarity, auxiliary functions such as adding PW envelope and three imaging modes and practical features such as real-time synchronization.It is widely used in the examination of abdomen, gynecology, obstetrics, urology,vascular, heart, small organs,andrology,musculoskeletal especially in the clinical examination of large medical institutions and primary medical system.Is a cost-effective color doppler ultrasound diagnostic instrument.

                             notebook full digital color ultrasound diagnosis system


Configuration:

1)Full-Digital 2D gray scale imaging

2)Full-Digital Tissue Harmonic Imaging (THI)

3)Color Doppler blood flow imaging

4)Directional color energy Doppler imaging

5)Pulse Wave Doppler imaging (PW)

6)Space compound imaging

7)2D, color, Doppler mode automatic optimization adjustment technology

8)Real-time triple synchronizing

9)Support 6 kinds language

10)Adaptive speckle suppression technology

11)Hand free 3D imaging(Optional)

12)Real-time 4D imaging(Optional)

13)Intelligent picture - in - picture imaging mode (PIP)

14)Monitor: 15 inch high resolution medical LCD monitor, adjustable angle

15)Probe connectors: ≥2  active

Multiple probe configuration:

1.1 Convex probe frequency: 2.0-5.0MHZ(multi-frequency, Harmonic frequency≥5 ), probe scanning angle 20°~85°, visible and adjustable.

1.2 Linear probe frequency: 6.0-12.0MHZ(multi-frequency, harmonic frequency ≥4 ), probe scanningwith trapezoidal imaging technology and 2D beam deflection technology

1.3 Trans-vaginal probe frequency: 5.0-8.0MHZ(multi-frequency, harmonic frequency ≥2 ), probe scanning angle 20°~160°, visible and adjustable.

1.4 Real time 3D (4D) volume probe frequency: 2.0-5.0MHz, 4 segments multi-frequency.

1.5 Micri-convex probe frequency: 4.0-6.0MHz, 3 segments multi-frequency.

Applications: abdominal, urology, OB&GYN,  paediatrics / neonatal, superficial / small organ, musculoskeletal, cardiology etc.

                           Portable color doppler ultrasound diagnostic system

Main technical specification

1.  2D,B/M,PDI,PW,CFM,4D, imaging mode

2. Gray scale: 256

3.  Gray Map: ≥16  level, visible and adjustable

4.  Dynamic range: 60-240db(visible and adjustable)

5. Resolution: Horizontal≤1mm; Vertical≤0.5mm

6. Under B mode, focus number: 1-6, focus position continuously adjustable

7.  STC gain control ≥8  segments

8. THI: harmonic frequency ≥2  segments

9. Line density: ≥256, visible and adjustable

10.  Preset: ≥40 kinds, users can customize the inspection conditions for the optimized images of different organs

11. Max scanning depth: ≥775px, visible and adjustable

12. Scanning angle: 50°-100°, visible and adjustable

13. Cine loop ≥4800 frames

14. Adaptive speckle suppressio: 0-100 adjustable

15. Amplification: overall amplification, local amplification, M-type amplification(do M-type sampling amplification under both scanning or freeze state)

16. Color gain: adjustable

17. Color frequency: ≥3 kinds, visible and adjustable

18. Sampling frame: size and position adjustab

19. PW  blood flow measurement speed: min speed: ≤0.2 cm/s, max speed: ≥37500px/s

20. PW  Doppler frequency: ≥3  kinds, CW Doppler frequency: ≥15 kinds, visible and adjustable

21.Real-time automatic Doppler envelope mapping and automatic measurement and analysis            

Measurement and analysis:

1 General measurement

2 OB&GYN measurement

3 Cardiac function measurement and analysis

4 Doppler blood flow measurement and analysis

5Peripheral blood vessel measurement and analysis

6 Urology measurement and analysis

7Orthopedic measurement and analysis

8Automatic Doppler flow measurement and analysis

9Users can programme protocol numbers, formulas and tables

7.1 Diagnostic report editable, embed the ultrasound diagnostic image in the report, and print directly

7.2 Hard disk  static and dynamic image storage 120G capacity

7.4 Input / output interface: HDMI port, video input/output port, S-VGA, print port, DICOM 3.0,USB port

Btw suggest XF3800 Doppler Ultrasound, E60 Plus Color Ultrasound, XF3600Vet Ultrasonic, E60 portable Ultrasound for reference, which are one of the top sales products in the past 2018.

And we have hospital and clinic project solution package, support you complete purchasing job. If any interest, welcome consult details

                                   notebook full digital color ultrasound diagnosis system

Main Technical Indexes:

The performance requirements of gray-scale imaging mode

The color ultrasonic at the gray-scale imaging performance mode should comply with the provisions of the table 1.1

Table 1.1 At the Gray-scale imaging mode the performance of the probe

performance   indexes

probe type and nominal   frequency

2.0≤f<4.0

2.0≤f<5.0

5.0≤f<8.0

5.0≤f<12.0

a) probe type and model

Micro-convex

Convex array

(type   TC60A)

Cavity

(type   TC10A)

Linear array

(type TL40A)

b) nominal frequency (MHz)

5

3.5

6.5

7.5

c) Scan depth(mm)

≥90

≥160

≥40

≥50

d) Lateral resolution (mm)

≤3(depth≤50)

≤4(80<depth≤60)

≤3(depth≤80)

≤4(80<depth≤130)

≤2(depth≤30)

≤2(depth≤40)

e) Axial resolution (mm)

≤2(depth≤50)

≤2(depth≤80)

≤3(80<depth≤130)

≤1(depth≤40)

≤1(depth≤50)

f) Blind area (mm)

≤7

≤5

≤4

≤3

g) Transverse geometry   precision (%)

≤20

≤15

≤10

≤10

h) Longitudinal geometric location   accuracy (%)

≤10

≤10

≤5

≤5

i) Slice thickness (mm)

≤5

≤5

≤5

≤5

j) Perimeter and area    measured deviation (%)

≤±20

≤±20

≤±20

≤±20

k)  M mode time   display error (%)

≤±10

≤±10

≤±10

≤±10

The performance requirements of color Doppler imaging mode:

a). The color Doppler imaging mode should comply with the provisions of thetable 1.2;

b). Color blood flow image should be essentially coincident with the gray-scale image of pipe's;

c). Blood flow direction should be able to correctly identify, no aliasing phenomenon;

Table1.2 at the color blood flow imaging mode the performance of the probe

Doppler model

Micro

Convex array

Cavity

Linear array

Investigation depth at Color   blood flow model

≥90mm

≥100mm

≥40mm

≥50mm

Investigation depth at   Doppler spectrum model

≥90mm

≥100mm

≥40mm

≥50mm

Blood flow speed reading   error

≤±15%

The performance requirements of Doppler spectrum mode:

a). The color ultrasonic at the color Doppler spectrum mode should comply with the provisions of the;

b). Blood flow speed reading error should comply with the provisions of the table2.3;

c). Pulse wave Doppler mode sampling area cursor position should be accurate;

Displayer: 15 inch LCD color display

Running hours: ≥8h;

Input power: ≤300VA;

Host weight: about 6 kg;

Host appearance size: 370 ×382×90(length × width × height) (mm3).

Standard Configuration:

1.     One host machine

2.     One  Li-battery

3.     One convex array probe:F=3.5MHZ 

        One  Linear probe: F=7-12Mhz 

        One  trans-vaginal probe: F=5-8Mhz         

4.     One power adapter

5.     Two USB port

6.     Svideo output port


Mr. Henry
skype Mr. Henry

Tel: 86-816-2536609
Fax: 86-816-2531598
Contact to this supplier

Didn't find what you're looking for? Post Buying Lead or contact HiSupplier Customer Service Center  for help!

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

MIANYANG XIANFENG MEDECAL INSTRUMENT CO.,LTD [China (Mainland)]


Business Type:Manufacturer, Trading Company, Service
City: Mianyang
Province/State: Sichuan
Country/Region: China (Mainland)

Selina:   skype
Vicky:   skype

You May Like: